Cloud Carbon Footprint: How to Measure the Emissions From Your Hosting

Carbon-neutral UK data centre

A cloud carbon footprint is the greenhouse gas emissions caused by the cloud services your organisation uses. It covers the electricity that powers and cools the servers, storage and networks in your provider’s data centres, plus a share of the emissions from making that hardware. You report it in tonnes of carbon dioxide equivalent (CO2e), usually as part of your Scope 3 emissions.

Our partners at Tunley Environmental, the sustainability consultancy that calculates our own footprint, have just published a clear guide to the carbon footprint of data and cloud hosting. It explains why moving to the cloud moves emissions rather than removing them, and what buyers should ask a provider. This post picks up from there, from the hosting side of the contract, as a provider of carbon neutral hosting. We explain how the numbers are built, which methods you can use, where the figures usually go wrong and what a useful answer from a provider looks like, using our own footprint as the example.

Quick facts

  • What it is: the emissions from the data centres, hardware and networks behind the cloud services you buy, expressed in CO2e.
  • Where it sits: in your Scope 3 (value chain) emissions, usually category 1, purchased goods and services. For your provider, the same electricity is usually its own Scope 2.
  • UK scale: data centres serving external customers used an estimated 4.5 TWh of grid electricity in Great Britain in 2024, about 2% of the total, according to the Office for National Statistics.
  • Main methods: spend-based (cost multiplied by an average factor), average-data (usage multiplied by a factor), supplier-specific (figures from your provider) and hybrid (a mix of the three).
  • Two electricity figures: location-based (the grid average) and market-based (reflecting renewable energy contracts). Ask for both.
  • Biggest trap: comparing figures that use different boundaries, scopes or allocation methods.

What is a cloud carbon footprint?

A cloud carbon footprint is the share of a provider’s emissions that belongs to the services you use. It is not the provider’s total footprint and it is not your whole digital footprint. It is the slice of data centre energy, cooling and hardware that your virtual servers, storage, backups and network traffic account for over a reporting period.

The important word is share. A hosting provider runs shared infrastructure for many customers. To give you a number, someone has to decide how to divide the total between them: by the computing power you reserve, the storage you hold, the hours you run, the money you spend or a mix. That decision, called allocation, changes the answer more than most people expect.

Tunley Environmental makes the same distinction in its guide. A provider’s corporate footprint and the emissions attributed to your service answer different questions. The first tells you how the provider is managing its own impact. The second tells you what to put in your own carbon report.

Key takeaway: before you compare two cloud carbon figures, check they measure the same thing. A whole-company total and a per-customer allocation are not interchangeable.


What makes up the carbon footprint of data and cloud hosting?

The carbon footprint of data comes from physical equipment that needs power and cooling, and from the emissions caused by making and disposing of that equipment. Some sources are large and well measured. Others are smaller, harder to measure or often left out of the boundary altogether.

SourceWhat it isUsually counted?
IT electricityPower drawn by servers, storage arrays and network switchesYes, the core of every assessment
Cooling and facility overheadsAir conditioning, fans, lighting, power conversion losses and backup systemsYes, often through power usage effectiveness (PUE)
Backup generatorsDiesel or other fuel burned during tests and outagesBy whoever owns the generators, as Scope 1
Grid lossesElectricity lost in transmission and distribution before it reaches the siteSometimes, as a separate Scope 3 item
Embodied carbonEmissions from mining, manufacturing, shipping and disposing of hardwareIncreasingly, but methods vary
Network transmissionEnergy used by the networks between the data centre and your usersDepends on the boundary
End-user devicesLaptops and phones used to reach the serviceUsually counted separately, not as hosting

Electricity is the largest operational source for most hosting. How much carbon that electricity carries depends on where and when it is used. The UK government’s greenhouse gas conversion factors for 2026 put UK electricity at 0.13096 kg CO2e per kWh used (the “electricity generated” factor, reported as Scope 2), with a further 0.01299 kg per kWh for transmission and distribution losses, reported as Scope 3.

Water use and electronic waste are real environmental impacts too. As Tunley Environmental points out, they should not be presented as carbon emissions unless a recognised method converts them into CO2e.


How big is the data centre carbon footprint in the UK?

UK data centres are a small but fast-growing share of electricity use. The Office for National Statistics reports that data centres serving external organisations, such as colocation, managed hosting and hyperscale sites, used an estimated 4.5 TWh of grid electricity in Great Britain in 2024. That was 2% of the 249.2 TWh consumed from the grid.

Use rose by 1.3 TWh, or 41%, between 2020 and 2024. Over the same period the number of these data centres in Great Britain went from 221 to 239. The figures exclude enterprise data centres that organisations run for their own use, so the full total is higher. You can read the detail in the ONS methodology article on data centres and the UK national accounts.

Globally, the International Energy Agency estimates that data centres used around 485 TWh of electricity in 2025, 17% more than the year before. Its updated projections, published in 2026, expect that to roughly double to around 950 TWh by 2030, about 3% of global electricity demand, with use by AI-focused data centres growing much faster than the rest. The figures are in the IEA’s Key Questions on Energy and AI report.

Facility efficiency has barely moved in recent years. The Uptime Institute Global Data Center Survey 2026 put the industry average power usage effectiveness at 1.52 among respondents, which Uptime describes as in line with a seven-year trend of relative stasis. In plain terms, for every 1 kWh used by IT equipment, an average facility used about another 0.52 kWh on cooling and other overheads.

MeasureFigureSource
GB data centre grid electricity, 20244.5 TWh, about 2% of grid useONS, from DESNZ data
Growth, 2020 to 20241.3 TWh, or 41%ONS
GB data centres counted, 2024239 (up from 221 in 2020)ONS
Global data centre electricity, 2025About 485 TWh, up 17% on 2024IEA
Global projection, 2030About 950 TWh, about 3% of global demandIEA, 2026 update
Average PUE, 2026 survey1.52Uptime Institute

Key takeaway: data centre emissions are not yet a large slice of the UK total, but data centres are one of the fastest-growing users of electricity. Buyers are right to start asking for the numbers now.


Does moving to the cloud reduce your carbon footprint?

Moving to the cloud can reduce the total energy needed to run a workload, but it does not make the emissions disappear. When servers sit in your own building, their electricity appears in your energy bills and your Scope 2. When the same work runs in a provider’s data centre, the electricity becomes the provider’s Scope 2 and part of your Scope 3. The emissions have changed hands.

Whether the total goes down depends on what you are comparing. A server room in an office, with domestic-grade air conditioning and machines running at low utilisation, is often less efficient than a purpose-built data centre where hardware is shared and cooling is managed by specialists. But a cloud estate full of idle virtual machines and forgotten storage can easily use more energy than it needs to.

Government-commissioned research supports the general case, with caveats. Two studies by Europe Economics for the Department for Energy Security and Net Zero, published on GOV.UK, compared the electricity used across the full delivery chain of digital services with physical alternatives.

In the first study’s three use cases, the digital option matched or used less electricity. The follow-up study, published on 28 July 2026, looked at ten more. It found that when workers use AI to be more productive it typically reduces electricity per task, but for other use cases digitalisation could either increase or reduce consumption depending on the service.

Both studies deliberately leave out any extra activity that digital services cause, so they compare like with like rather than predicting total demand.

So the honest answer to “is cloud computing bad for the environment?”, and to most questions about the environmental impact of cloud computing, is that it depends on the workload, the facility, the electricity and what you would otherwise do. That is why measurement matters more than general claims.

Key takeaway: moving to the cloud moves your hosting emissions, the cloud emissions you are responsible for, from Scope 2 to Scope 3. It only reduces them if the new setup actually uses less energy, or cleaner energy, than the old one.


Which scope do cloud hosting emissions fall under?

For most organisations, cloud hosting emissions are Scope 3, category 1: purchased goods and services. The GHG Protocol Corporate Value Chain (Scope 3) Standard sets out 15 Scope 3 categories. The first, purchased goods and services, is where bought-in IT services such as cloud hosting usually belong.

The UK government’s conversion factors guidance also treats electricity used in assets you do not own or operate, such as space in a data centre, as Scope 3.

The picture looks different from the provider’s side:

OrganisationEmissionScope
Hosting providerElectricity bought for its data centres or rack spaceScope 2, or Scope 3 for space in a data centre it does not own or operate, depending on its lease and boundary
Hosting providerFuel burned in backup generators it ownsScope 1
Hosting providerHardware it buys, colocation services, staff travelScope 3
You, the customerYour share of the provider’s emissionsScope 3, category 1
You, if you colocate your own serversElectricity for your equipmentScope 2 or 3, depending on your lease and reporting boundary

This chain matters for public sector work. Our guide to how much energy cloud storage uses explains the Scope 2 and Scope 3 treatment of hosting electricity in more detail, with a worked example.


How do you calculate the carbon footprint of cloud computing?

The GHG Protocol’s Scope 3 calculation guidance sets out four methods for purchased goods and services, which you can use to estimate the carbon footprint of cloud computing. They trade accuracy against effort. Most organisations start with the simplest method and move to better data for their largest services.

MethodHow it worksStrengthsWeaknesses
Spend-basedMultiply what you spend on a service by an average emissions factor for that type of spendQuick, uses data you already holdCrude. A price rise looks like more emissions, a discount like less
Average-dataMultiply your usage (kWh, server hours, terabytes stored) by an industry-average factorReflects how much you actually useIgnores how efficient your provider really is
Supplier-specificUse emissions figures from your provider, allocated to your serviceThe most relevant figure for your contractDepends on the provider’s method, boundary and honesty
HybridCombine supplier data for some parts with averages for the gapsPractical for most estatesNeeds a clear note of what came from where

A practical way to build your cloud carbon footprint looks like this:

  1. List every cloud service. Include hosting, virtual servers, storage, backup, disaster recovery, software as a service and anything else run on someone else’s hardware. Tunley Environmental recommends recording the supplier, service type, reporting period, usage and any emissions data supplied.
  2. Find the material ones. A handful of services usually make up most of your spend and usage. Focus your effort there first.
  3. Choose a method for each. Spend-based for small services, supplier-specific where your provider can give you a credible figure.
  4. Ask each main provider for data. Use the questions later in this guide. Note what the figure covers and how it was allocated.
  5. Calculate and record your assumptions. Write down the method, the factors and the year, so next year’s figure can be compared fairly.
  6. Replace estimates with better data over time. Each contract renewal is a chance to ask for more.

If your provider can give you energy use in kWh for your services, you can turn it into carbon yourself. Multiply the kWh by the UK government factor for the right year. For example, 10,000 kWh at the 2026 UK factor of 0.13096 kg per kWh comes to about 1,310 kg CO2e, or 1.3 tonnes, before transmission and distribution losses.

Key takeaway: a spend-based figure is a starting point, not an answer. The more of your hosting footprint you can base on real usage and supplier data, the more useful it becomes.


What is the difference between location-based and market-based emissions?

Location-based emissions use the average carbon intensity of the grid where the electricity is consumed. Market-based emissions reflect the electricity a company has chosen to buy through contracts, such as a renewable tariff backed by certificates. The same data centre can report two very different numbers depending on which method is used.

That is why location based vs market based emissions is one of the first things to check in any cloud carbon claim.

The GHG Protocol Scope 2 Guidance asks companies to report both. The UK’s Environmental Reporting Guidelines, as summarised in the government’s conversion factors guidance, require the location-based figure for Scope 2 and allow the market-based figure in addition.

Location-basedMarket-based
What it showsThe average emissions of the local gridThe emissions of the electricity contracts the company holds
Based onGovernment grid factors, such as the UK’s 0.13096 kg CO2e per kWh for 2026Supplier tariffs, Renewable Energy Guarantees of Origin (REGOs) and power purchase agreements
Can a renewable tariff reduce it?NoYes, if the contract meets the GHG Protocol’s quality criteria
Best forSeeing the real physical impact on the gridSeeing the effect of a company’s purchasing choices

Neither number is wrong. They answer different questions. A provider that reports a near-zero market-based figure is telling you about its energy contracts. The location-based figure tells you how much electricity it actually uses and what that electricity typically emits on the UK grid. Tunley Environmental advises asking which contractual instruments support any renewable claim, and whether a location-based figure is also available. We agree.

The method itself is under review. The GHG Protocol consulted on changes to its Scope 2 Guidance between 20 October 2025 and 31 January 2026. The 2015 guidance still applies while the revision continues, so check which version your reporting framework follows.


What about embodied carbon in servers?

Embodied carbon is the greenhouse gas emitted in making, transporting and eventually disposing of a product. For hosting, that means the servers, storage arrays, switches and racks, along with the batteries and other plant inside the building. It is counted once, when the equipment is made, and then spread over its working life.

Embodied carbon is easy to miss because it happens before the hardware is switched on. As grids get cleaner and operational emissions per kWh fall, the share of a server’s lifetime footprint that comes from manufacturing grows. That makes hardware lifespan an important lever. Keeping equipment in service for longer, repairing it, reusing parts and recycling responsibly at the end all spread the embodied emissions further.

Ask your provider whether its footprint includes embodied emissions from hardware, and if so, how it estimates them. Many providers, especially smaller ones, do not yet have product-level data from every manufacturer. Some hardware makers publish product carbon footprints, which helps. Tunley Environmental suggests asking how equipment is maintained, repaired, reused and treated at end of life. The answer shows whether a provider is thinking about the whole lifecycle or only the electricity bill.


What should you ask your hosting provider?

The most useful questions test what a provider’s figure covers, how good the evidence is and whether it relates to your service. Tunley Environmental’s guide lists five. We have added two more of our own, the last two in the table, and what a useful answer looks like from the point of view of a provider that has to answer them.

QuestionWhy it mattersA useful answer includes
Do you measure your organisational carbon footprint?Shows whether the provider knows its own impactScopes covered, reporting period, who calculated it and whether it was independently checked
Can you provide emissions data for our service?Your report needs your share, not the company totalThe allocation method (by capacity, usage or spend) and what is included
How is the infrastructure powered?Renewable claims vary widely in qualityBoth location-based and market-based figures, and the contracts or certificates behind any renewable claim
What reduction initiatives are in place?Measurement without action does not lower emissionsSpecific changes to equipment, utilisation, energy or procurement, with results tracked over time
How do you manage equipment over its life?Embodied carbon is a growing share of the totalHow hardware is maintained, reused and recycled, and whether embodied emissions are estimated
Do you hold any verified carbon standard?Independent checks reduce the risk of greenwashingThe standard, the edition, the year it covers and who verified it
Can you give us energy use in kWh?Lets you apply the correct UK factors yourselfkWh by service or by period, with a note on whether cooling is included

A provider may not have everything in the ideal format yet. That is normal, and it is better to say so than to send a figure that cannot bear scrutiny. What you are looking for is a clear boundary, a stated method and a plan to improve the data.

Key takeaway: ask for the method as well as the number. A carbon figure without a boundary and an allocation method is not comparable with anything.


What does a hosting provider’s own carbon footprint look like?

A provider’s organisational footprint covers everything the business does in a year: its data centre electricity, offices, travel, purchased hardware and services. It is a whole-company figure, so it shows how the provider is managing its impact rather than the emissions of any single customer’s service.

Here is ours, as an example. Tunley Environmental has now completed three operational carbon assessments for us. As Tunley Environmental’s article reports, our Carbon Reduction Plan records an organisational footprint of 165 tonnes CO2e for 1 November 2023 to 31 October 2024. Tunley’s article also reports that our 2024/25 assessment showed a 6.2% fall in market-based emissions compared with 2023/24, and a 13.6% fall in our carbon intensity ratio relative to operations.

MeasureFigure
Organisational footprint, 1 November 2023 to 31 October 2024165 tonnes CO2e
Change in market-based emissions, 2024/25 against 2023/24Down 6.2%
Change in carbon intensity ratio, 2024/25 against 2023/24Down 13.6%
Carbon neutralityVerified by BSI under ISO 14068-1:2023 for 2025
Calculated byTunley Environmental

Two points are worth drawing out. First, we track intensity as well as the total. A growing business can cut the emissions of each unit of work while its total still rises, so both numbers are needed to see what is really happening. Second, the 6.2% figure is market-based. The location-based figure answers a different question, as explained above, so ask any provider for both, including us.

Our carbon neutrality for 2025 was independently verified by BSI under ISO 14068-1:2023, which was then the international standard for carbon neutrality. Under that standard, a carbon neutrality claim needs a measured footprint, a plan that puts emission reductions and removals ahead of offsetting, and offsetting only for what remains. You can read about it on our ISO 14068-1 carbon neutral page.

In September 2026 ISO replaced ISO 14068-1:2023 with ISO 14068:2026. ISO says the new edition changes only the title and number, so any future verification would be against ISO 14068:2026. We explain what ISO 14068 carbon neutrality means for hosting customers in a separate guide.

None of these figures is the footprint of your service. They show the scale, the direction of travel and the method. If you need a figure for your own reporting, that is the conversation to have with us, and the questions above are the right place to start.


How can you reduce the carbon footprint of your cloud hosting?

The most effective way to reduce your cloud carbon footprint is to stop paying for computing you do not use. Idle and oversized resources draw power around the clock. Most of the steps below also reduce cost, which makes them easier to justify.

  • Right-size servers. Match the processor and memory you reserve to what workloads actually use. Many virtual machines are provisioned for a peak that never comes.
  • Switch off what is idle. Development and test environments often run all night and at weekends. Schedule them, or remove them when the project ends.
  • Set data retention rules. Keep data for a defined business, legal or recovery reason, then delete it. Storage that is never read still needs power and hardware.
  • Review your backups. Keep the copies your recovery plan needs, such as those under the 3-2-1 rule, without holding unlimited versions forever.
  • Consolidate. Fewer, better-utilised servers usually use less energy than many lightly loaded ones.
  • Ask about hardware lifecycle. Efficient modern hardware uses less power per unit of work, but replacing it too early adds embodied carbon. A good provider balances the two.
  • Use contract renewals. Make carbon data and reduction commitments part of the procurement criteria, and compare each year’s figures with the last.

Any change must keep your security, resilience and recovery requirements intact. A smaller footprint is no good if a restore fails. Involve your IT owners from the start, as Tunley Environmental recommends, and let your sustainability team set the accounting method so the results are consistent.

Key takeaway: the cheapest kilowatt-hour is the one you never use. Waste reduction is where cloud sustainability, digital sustainability and cost control all meet.


How do you spot greenwashing in cloud sustainability claims?

Greenwashing is a claim that makes a product or company sound better for the environment than the evidence supports. In hosting, the warning signs are claims with no boundary, no method and no independent check, such as “green cloud hosting” or “100% renewable” with nothing to back it up. Green cloud computing is a worthwhile goal, but the label alone tells you nothing.

The Competition and Markets Authority’s Green Claims Code says environmental claims must be truthful, accurate, clear and substantiated, and must not omit important information. Its principles are a useful test for any provider, and we apply them to our own claims. Ask what the claim covers, what evidence supports it, which standard it follows and who checked it.

We cover this in more depth in our guide to spotting greenwashing in green hosting.


How BlackBox Hosting can help

BlackBox Hosting runs UK private cloud, sovereign cloud, backup and disaster recovery from UK data centres. We hold ISO 14001 for environmental management, and BSI has verified our carbon neutrality under ISO 14068-1:2023 for 2025. Tunley Environmental calculates our carbon footprint, so the figures behind our claims come from an independent specialist.

If you are building your own cloud carbon footprint, we can talk you through how our footprint was measured, what it covers and how our services fit into your Scope 3 reporting. Our carbon neutral hosting page, linked at the top of this guide, explains the service in more detail.

To talk about your hosting and its carbon footprint, talk to an expert, or start a 30-day free trial.


Frequently asked questions

What is a cloud carbon footprint?

A cloud carbon footprint is the greenhouse gas emissions caused by the cloud services an organisation uses. It covers the electricity for servers, storage, networking and cooling in a provider’s data centres, plus a share of the emissions from making the hardware, reported in tonnes of CO2e.

Is cloud computing bad for the environment?

It depends on the workload, the facility and the electricity. Purpose-built data centres with well-utilised hardware can use less energy than an office server room, but idle or oversized cloud resources waste power. Moving to the cloud moves emissions to your provider rather than removing them.

Which scope are cloud hosting emissions?

For a customer, cloud hosting emissions are usually Scope 3, category 1, purchased goods and services. For the hosting provider, the electricity it buys for its data centres is usually its own Scope 2, and fuel burned in backup generators it owns is Scope 1.

How do I calculate my cloud carbon footprint?

List your cloud services, find the largest ones and choose a method for each. A spend-based estimate multiplies cost by an average factor. An average-data estimate uses your usage. A supplier-specific figure comes from your provider. Record your method so you can compare years fairly.

What is the difference between location-based and market-based emissions?

Location-based emissions use the average carbon intensity of the local grid. Market-based emissions reflect the electricity a company buys through contracts, such as certificate-backed renewable tariffs. The GHG Protocol asks companies to report both, because they answer different questions.

What is embodied carbon in data centres?

Embodied carbon is the emissions from making, transporting and disposing of hardware such as servers, storage arrays and switches. It is spread over the equipment’s working life, so keeping hardware in service for longer, repairing it and reusing it lowers the embodied share of each year’s footprint.

What should I ask a hosting provider about carbon?

Ask whether it measures its footprint, what scopes and period are covered and who checked it. Ask for emissions or energy data for your service, the allocation method, both location-based and market-based electricity figures, and how it manages hardware over its life.

Does carbon neutral hosting mean zero emissions?

No. Carbon neutral means a provider has measured its emissions, is working to reduce them and has offset what remains, ideally verified against a standard such as ISO 14068. The servers still use electricity, so it still makes sense to measure and reduce your share.